Prediction of Wind-Induced Responses and Wind Loads
The Recommendations for Wind Loads of Buildings and Structures of the Architectural Institute of Japan have now been updated. This paper presents the drafts of the new Recommendations...

Tuned Mass Dampers for Towers and Buildings
Tuned mass dampers (TMD's) are used to reduce the response of tall slender structures to resonant wind-induced oscillations. This paper reviews the authors' experience with the design...

Fluid Viscous Damper for Improving the Earthquake Resistance of Buildings
Experimental results are presented which demonstrate that the use of fluid dampers as add-on devices in moment resisting frames substantially increases damping and reduces seismic story...

Evaluation of Seismic Isolation Schemes for a Historic Building
The U.S. Court of Appeals Ninth District building originally completed in 1905 with an expansion in 1933, suffered damage during the 1989 Loma Prieta earthquake. The building is currently...

Wind-Induced Vibrations of Tall Buildings Using Tuned Mass Damper
A Lagrange formulation is applied to tall buildings using tuned mass damper. The resulting equations of motion are analyzed using a frequency window method. The method reduces the computational...

A Shear Transfer Model for Floor-To-Wall Connections in Concrete Masonry Structures
Based upon experiments conducted at the Univ of California, San Diego (UCSD) on floor-to-wall connections in concrete masonry structures, a constitutive model was developed for the overall...

Analysis of Masonry Walls with Smeared and Discrete Crack Models
To design modern reinforced masonry structures for seismic loads and to evaluate the seismic safety of existing unreinforced masonry buildings, the shear resistance of masonry shear walls...

Behavior and Design of Angle Connections Subjected to Cyclic Axial Force and Shear
The objectives of this study were to establish cyclic behavior of double angle shear connections subjected to axial load and to develop design recommendations. Five cyclic tests of double...

Interaction Between Beam and Steel Connections
The overall objective of the investigation is to study the behavior of a particular steel connection type, flush end plate steel connections, subjected to shear, axial forces, and possibly...

The Effect of Nonlinear Drag PSD on Fatigue of Compliant Offshore Structures
Structural fatigue damage induced by random ocean wave loading on a compliant type of offshore structure is considered. The nonlinear wave force is modeled by the Morison equation and...

Flexural and Shear Behavior of Combined Concrete and Graphite Epoxy Beams
An experimental and analytical study of six graphite composite beams are presented. Four of the beams incorporated a reinforced concrete slab. The composite action and the effect of concrete...

The Innovative Concept of Semi-rigid Composite Beam
This paper discusses invention and development of a new type of composite beam called 'Semi-rigid Composite Beam.' This new type of beam is expected to behave better than presently used...

Field Measurements of Wind-Induced Pressures on Roofs of Low Buildings
Full-scale measurements have been carried out on an experimental building, 3.3 m high, beside the football field at the Loyola campus of Concordia University. Wind-induced pressures have...

Three-Dimensional Stability Analysis of Carpenter Dam
This paper describes the three-dimensional stability analysis of Carpenter Dam. The presence of keyed construction joints between dam monoliths at Carpenter Dam can significantly affect...

In Situ Testing Performed at Jackson Lake Dam
Jackson Lake Dam was rehabilitated from 1986 to 1988 to increase seismic stability. Final foundation improvements consisted of dynamic compaction and mixed inplace soil cement columns....

Graham Lake Dam Remedial Measures Project
Graham Lake Dam consists of a 550-foot long earth embankment and an 80-foot long concrete spillway. Several concerns were identified during project inspections including limited spillway...

Seismic Rehabilitation of Sardis Dam
Extensive subsurface investigation of the embankment dam revealed the existence of a weak layer of silt and soft clay in the original topstratum clay underlaying the upstream shell of...

Seismic Stability Modification Requirements for Pineview Dam
Pineview Dam is located 8 km upstream from Ogden, Utah, and about 8 km from the Wasatch Fault Zone. Preconstruction information and construction records available at the outset of the...

Open Channels in Fractures Maintained by Deposition and Erosion of Colloids
Colloids initially suspended in the water in fractures can deposit onto the fracture surfaces, and will partially or fully clog the fracture. The amount of clogging will depend on whether...

Thin-Walled Finite Element for Curved Multicell Box Girders
The generalized Vlasov's thin-walled beam theory was combined with the finite element technique to develop a new curved thin-walled multicell box girder finite element which can model...

 

 

 

 

Return to search